Search results for "beam [electron]"

showing 10 items of 433 documents

Three-dimensional images contribute to the diagnosis of mucous retention cyst in maxillary sinus

2011

Objective: To evaluate the detection of mucous retention cyst of maxillary sinus (MRCMS) using panoramic radiography and cone beam computed tomography (CBCT). Study Design: A digital database with 6,000 panoramic radiographs was reviewed for MRCMS. Suggestive images of MRCMS were detected on 185 radiographs, and patients were located and invited to return for follow-up. Thirty patients returned, and control panoramic radiographs were obtained 6 to 46 months after the initial radiograph. When MRCMS was found on control radiographs, CBCT scans were obtained. Cysts were measured and compared on radiographs and scans. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical…

AdultMalemedicine.medical_specialtyCone beam computed tomographyPanoramic radiographMaxillary sinusAdolescentRadiographyOdontologíaYoung AdultImaging Three-DimensionalRadiography PanoramicmedicineParanasal Sinus DiseasesHumansStatistical analysisChildGeneral Dentistrybusiness.industryMucous retention cystCystsClinical and Experimental dentistryCone-Beam Computed TomographyMaxillary SinusMiddle Agedrespiratory systemmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludrespiratory tract diseasesmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryFemaleResearch-ArticleRadiologybusiness
researchProduct

Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions

2014

Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…

AdultMalemedicine.medical_specialtyLung NeoplasmsInitial SeedAutomated segmentationBreast NeoplasmsTumor responseSensitivity and SpecificityMultidetector Computed TomographyImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationTumor growthAgedMathematicsAged 80 and overbusiness.industryLiver NeoplasmsPattern recognitionSpiral Cone-Beam Computed TomographyGold standard (test)Middle AgedTumor BurdenEffective diameterLiverKernel (statistics)FemaleArtificial intelligenceRadiologyColorectal NeoplasmsbusinessSoftwareRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Efficient transfer of positrons from a buffer-gas-cooled accumulator into an orthogonally oriented superconducting solenoid for antihydrogen studies

2012

Positrons accumulated in a room-temperature buffer-gas-cooled positron accumulator are efficiently transferred into a superconducting solenoid which houses the ATRAP cryogenic Penning trap used in antihydrogen research. The positrons are guided along a 9 m long magnetic guide that connects the central field lines of the 0.15 T field in the positron accumulator to the central magnetic field lines of the superconducting solenoid. Seventy independently controllable electromagnets are required to overcome the fringing field of the large-bore superconducting solenoid. The guide includes both a 15° upward bend and a 105° downward bend to account for the orthogonal orientation of the positron accu…

Antiparticlesuperconductivity [solenoid]Physics::Instrumentation and DetectorsPenning trapGeneral Physics and Astronomybeam transportSuperconducting magnetlaw.inventionenergy spectrum [positron]Nuclear physicslawddc:530AntihydrogenPhysicsElectromagnetspatial distribution [magnetic field]ATRAPPenning trapMagnetic fieldbeam opticscryogenicsAntimatterMagnetPhysics::Accelerator Physicsaccumulator [positron]Atomic physicsperformanceNew Journal of Physics
researchProduct

Fixed point theorems on ordered metric spaces and applications to nonlinear elastic beam equations

2012

In this paper, we establish certain fixed point theorems in metric spaces with a partial ordering. Presented theorems extend and generalize several existing results in the literature. As application, we use the fixed point theorems obtained in this paper to study existence and uniqueness of solutions for fourth-order two-point boundary value problems for elastic beam equations.

Applied MathematicsMathematical analysisFixed-point theoremFixed-point propertyNonlinear systemMetric spaceSettore MAT/05 - Analisi MatematicaModeling and SimulationGeometry and TopologyBoundary value problemUniquenessOrdered metric space fixed point coupled fixed point boundary value problem elastic beam equation.Partially ordered setCoincidence pointMathematics
researchProduct

MBE growth and properties of low-density InAs/GaAs quantum dot structures.

2011

We present the results of a comprehensive study carried out on morphological, structural and optical properties of InAs/GaAs quantum dot structures grown by Molecular Beam Epitaxy. InAs quantum dots were deposited at low growth rate and high growth temperature and were capped with InGaAs upper confining layers. Owing to these particular design and growth parameters, quantum dot densities are in the order of 4-5x109 cm-2 with emission wavelengths ranging from 1.20 to 1.33 µm at 10 K, features that make these structures interesting for single-photon operation at telecom wavelength. High resolution structural techniques show that In content and composition profiles in the structures depend on …

Arrhenius equationeducation.field_of_studystructural and optical characterizationPhotoluminescenceMaterials scienceCondensed matter physicslow-dimensional semiconductor systemsCondensed Matter::OtherPopulationmolecular-beam epitaxyGeneral ChemistryCondensed Matter PhysicsEpitaxyCondensed Matter::Mesoscopic Systems and Quantum Hall Effectlow-dimensional semiconductor systems molecular-beam epitaxy structural and optical characterizationsymbols.namesakeCondensed Matter::Materials ScienceQuantum dotQuantum dot lasersymbolsGeneral Materials ScienceeducationMolecular beam epitaxyWetting layer
researchProduct

Cone-beam computed tomography and its applications in dental and maxillofacial radiology.

2020

Cone-beam computed tomography (CBCT) was first used in dental and maxillofacial radiology (DMFR) at the end of the 1990s. Since then, it has been successfully established as the standard three-dimensional radiographic imaging technique in DMFR, with a wide variety of applications in this field. This manuscript briefly reviews the background information on the technology and summarises available data on effective dose and dose optimisation. In addition, typical clinical applications and indications of the technique in DMFR are presented.

Background informationCone beam computed tomographymedicine.medical_specialtymedicine.diagnostic_testRadiographic imagingbusiness.industryStomatognathic DiseasesComputed tomographyGeneral MedicineCone-Beam Computed TomographyRadiation DosageFacial Bones030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineImaging Three-Dimensional030220 oncology & carcinogenesismedicineMaxillaDose optimisationHumansRadiology Nuclear Medicine and imagingRadiologybusinessClinical radiology
researchProduct

A beam theory for layered composites subjected to uniformly distributed load

2015

A theory for multilayered composite beams undergoing transverse uniformly distributed loads is presented. The formulation starts by assuming a layer-wise kinematical model characterized by third order approximation of the axial displacements and fourth order approximation of the transverse displacements. By enforcing the point-wise balance equations as well as the interface continuity conditions, the layer-wise kinematical model is rewritten in terms of a set of generalized kinematical variables associated with the beam as a whole. Stress resultants are then obtained in terms of the generalized variables derivatives and of the normal stresses applied to the top and bottom surfaces of the la…

Beam Theory Multilayered Composite Analytical SolutionSettore ING-IND/04 - Costruzioni E Strutture Aerospaziali
researchProduct

Stiffness and strength of composite truss beam to R.C. column connection in MRFs

2015

Abstract The results of experimental and numerical investigations on the cyclic behavior of composite truss beam to reinforced concrete column connection of moment resisting frames are reported. The beams are constituted by a steel truss and end zone added rebar embedded within a concrete block cast in place, so that, after curing, the steel truss and the added rebar work together with the concrete matrix as reinforcement of the composite beam. Particularly, three specimens of two-span continuous beams were tested under monotonic and cyclic actions as three point bending test. With the goal to investigate about the behavior of the end zone of the beam integrated into a moment resisting fram…

Beam-to-column connection; Cyclic behavior of beam end zone; Experimental three-point bending tests; Fiber model; Hybrid steel trussed-concrete beams; Building and Construction; Civil and Structural Engineering; Mechanics of MaterialsExperimental three-point bending testMaterials scienceThree point flexural testRebarTrusslaw.inventionBeam-to-column connectionFiber modellawmedicineMechanics of MaterialHybrid steel trussed-concrete beamComposite materialCivil and Structural Engineeringbusiness.industryMetals and AlloysStiffnessStructural engineeringBuilding and ConstructionExperimental three-point bending testsReinforced concrete columnCyclic behavior of beam end zoneStrength of materialsSettore ICAR/09 - Tecnica Delle CostruzioniHybrid steel trussed-concrete beamsMechanics of MaterialsPlastic hingemedicine.symptom2506businessBeam (structure)
researchProduct

Minor changes in the macrocyclic ligands but major consequences on the efficiency of gold nanoparticles designed for radiosensitization

2016

International audience; Many studies have been devoted to adapting the design of gold nanoparticles to efficiently exploit their promising capability to enhance the effects of radiotherapy. In particular, the addition of magnetic resonance imaging modality constitutes an attractive strategy for enhancing the selectivity of radiotherapy since it allows the determination of the most suited delay between the injection of nanoparticles and irradiation. This requires the functionalization of the gold core by an organic shell composed of thiolated gadolinium chelates. The risk of nephrogenic systemic fibrosis induced by the release of gadolinium ions should encourage the use of macrocyclic chelat…

BiodistributiontumorMaterials scienceGadoliniumchemistry.chemical_elementNanoparticleContext (language use)Nanotechnology02 engineering and technology[CHIM.THER]Chemical Sciences/Medicinal Chemistry010402 general chemistry01 natural sciences[ CHIM ] Chemical Sciencesnephrogenic systemic fibrosis[CHIM]Chemical SciencesGeneral Materials ScienceChelationratbiodistributionradiotherapyrenal clearance[ CHIM.THER ] Chemical Sciences/Medicinal Chemistry021001 nanoscience & nanotechnologyCombinatorial chemistry0104 chemical scienceschemistrymri contrast agentsColloidal goldSurface modification0210 nano-technologySelectivitydihydrolipoic acidmicrobeam radiation-therapy9l gliosarcoma
researchProduct

Nasal anomalies review with CT or MRI: from congenital to malignant.

2014

Learning Objectives. To describe imaging findings of a wide spectrum of uncommon nasal cavity masses evaluated at our institution by CT, CBCT and MR imaging, clinically and pathologically proven. Background. In this work we present a succinct review of disease illustrated by a retrospective case series of nasalcavity masses, evaluated at our institution. between 2010 and 2013. Patients have been studied with different imaging modalities including multiraw computed tomography (CT), cone beam computed tomography (CBCT) and magnetic resonance imaging (MR) to illustrate the findings and to summarize the main diagnostic keypoints for the differential diagnosis of nasal masses. Clinicopathologica…

CONE BEAM CTMAGNETIC RESONANCENOSECOMPUTED TOMOGRAPHYMASSDIFFERENTIAL DIAGNOSIS
researchProduct